EJA438W/EJA438N
A Capsule
|
EJA438W
B Capsule
|
EJA438N
B Capsule
|
Range
|
-0.1 to 3 MPa
(-15 to 430 psi)
|
-0.1 to 14 MPa
(-15 to 2000 psi)
|
-0.1 to 7 MPa
(-15 to 1000 psi)
|
Span
|
0.06 to 3 MPa
(8.6 to 430 psi)
|
0.46 to 14 MPa
(66 to 2000 psi)
|
0.46 to 7 MPa
(66 to 1000 psi)
|
Accuracy
|
±0.2%
|
±0.2%
|
±0.2%
|
Degrees of protection
|
IP67, NEMA 4X, and JIS C0920 immersion proof
|
Certificates
|
FM, CENECEC ATEX, CSA, TIIS, IECEx
|
Output
|
4 to 20 mA DC or FOUNDATION™ Fieldbus or PROFIBUS PA 2-wire system with digital communication
|
Supply voltage
|
BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type)
Fieldbus:9 to 32 V DC (9 to 24 V DC for Entity model and 9 to 17.5 V DC for FISCO model)
|
Ambient temperature
|
-40 to 60 deg C (-40 to 140 deg F) (general use type)
-30 to 60 deg C (-22 to 140 deg F) (with integral indicator)
It must be within the fill fluid operating temperature range
|
Process temperature
|
-50 to 300 deg C (-58 to 572 deg F)
It must be within the fill fluid operating temperature range
|
Maximum working pressure
|
Max. measurement range valve
The working pressure must be within the flange rating.
|
Mounting
|
Transmitter: 2-inch pipe mounting
Diaphragm seal: flange mounting
|
Process flange size
|
Flush type: 3-inch (80mm), 2-inch (50mm)
Extended type: 4-inch (100mm), 3-inch (80mm)
|
Diaphragm material
|
SUS316L, Hastelloy C-276, Tantalum, Titanium
|
Process flange material
|
S25C, SUS304, SUS316
|
Housing
|
Cast aluminum alloy or SUS316 equivalent stainless steel (optional)
|