Features:
- Manufactured by Rosemount
- Absolute of gage pressure measurement
- For pressures up to 4000 psi
- Accuracy: ±0.10%
- Rangeability: 20:1
- Integral manifold
- Stainless steel or Hastelloy wetted materials
- Smart communications
- External push button zero and span capabilities
Specifications
(Zero-based spans, reference conditions, silicone oil fill, and 316LSST isolating diaphragm.)
Reference Accuracy
• ±0.10% of calibrated span. Includes combined effects of linearity, hysteresis, and repeatability
• ±0.075% of calibrated span (high accuracy option)
Ambient Temperature Effect
Expressed as a total effect per 50 °F (28 °C)
Total effect includes zero and span effects.
± (0.15% URL + 0.15% of span) from –40 °F to 185 °F(-40 °C to 85 °C)
Stability
±0.10% of URL for 12 months
Vibration Effect
Less than ±0.1% of URL when subjected to vibration of: peak to peak constant displacement of 4 mm (5–15 Hz) and constant acceleration of 2 g (15–150 Hz) and 1 g (150–2000 Hz).
Power Supply Effect
Less than 0.01% of calibrated span per volt
Mounting Position Effect
Zero shift of up to 1.2 inH2O (0.30 kPa), which can be calibrated out. No span effect.
Reference Accuracy: ± 0.10% of Span
Rangeability: 20:1
Installed Stability of ± 0.10% of URL for 12 months
Protocols available include 4-20mA HART®and 1-5 Vdc HART Low Power
Measurement Type
|
Gage, Absolute
|
Outputs
|
HART, Low Power HART
|
Reference Accuracy
|
± 0.10% of Span
|
Stability
|
± 0.10% of URL for 12 months
|